Chlorine sensors and transmitters for water treatment (2024)

Chlorine sensors and transmitters for water treatment (1)

F

L

E

X

  • Simple products

  • Easy to select, install and operate

Technical excellence

Simplicity

  • Standard products

  • Reliable, robust and low-maintenance

Technical excellence

Simplicity

  • High-end products

  • Highly functional and convenient

Technical excellence

Simplicity

  • Specialized products

  • Designed for demanding applications

Technical excellence

Simplicity

Variable

FLEX selections Technical excellence Simplicity
  • F
  • L
  • E
  • X

Fundamental selection

Meet your basic measurement needs

Technical excellence
Simplicity
  • F
  • L
  • E
  • X

Lean selection

Handle your core processes easily

Technical excellence
Simplicity
  • F
  • L
  • E
  • X

Extended selection

Optimize your processes with innovative technologies

Technical excellence
Simplicity
  • F
  • L
  • E
  • X

Xpert selection

Master your most challenging applications

Technical excellence
Simplicity

Variable

  • Learn more about the FLEX selections
Chlorine sensors and transmitters for water treatment (2)

4-channel transmitter Liquiline CM444

4-channel transmitter Liquiline CM444

Expandable multiparameter field device for all industries

Chlorine sensors and transmitters for water treatment (3)

Loading price

Prices temporarily unavailable

Price after login

Price on request

activating price

price: provide information

from € 99'999'999.99

Input 1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional

Output / communication 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet

Ingress protection IP66 / IP 67

Chlorine sensors and transmitters for water treatment (6)

F

L

E

X

Chlorine sensors and transmitters for water treatment (7)

Digital chlorine dioxide sensorMemosens CCS50E

Digital chlorine dioxide sensorMemosens CCS50E

Memosens sensor for drinking water, process water and multi-industry utilities

Measuring range Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
High: 0 to 200 mg/l ClO2

Process temperature 0 to 55 °C , non-freezing
(32 to 130 °F)

Process pressure Max. 2 bar abs
(Max. 29 psi abs)

Chlorine sensors and transmitters for water treatment (11)

F

L

E

X

Chlorine sensors and transmitters for water treatment (12)

Digital free chlorine sensorMemosens CCS51E

Digital free chlorine sensorMemosens CCS51E

Memosens sensor for drinking water, pool and process water as well as utilities in all industries

Chlorine sensors and transmitters for water treatment (13)

Loading price

Prices temporarily unavailable

Price after login

Price on request

activating price

price: provide information

from € 99'999'999.99

Measuring range Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
High: 0 to 200 mg/l HOCl

Process temperature 0 to 55 °C (32 to 130 °F), non-freezing

Process pressure Max. 1 bar (max. 14.5 psi)

Measuring method Closed, membrane covered measuring cell
Reduction of free chlorine at the cathode

Chlorine sensors and transmitters for water treatment (16)

F

L

E

X

New

Chlorine sensors and transmitters for water treatment (17)

Digital total chlorine sensorMemosens CCS53E

Digital total chlorine sensorMemosens CCS53E

Memosens disinfection sensor for wastewater and utilities in all industries

Chlorine sensors and transmitters for water treatment (18)

Loading price

Prices temporarily unavailable

Price after login

Price on request

activating price

price: provide information

from € 99'999'999.99

Measuring range 0 to 5 mg/l total chlorine or
0 to 20 mg/l total chlorine

Process temperature 0 to 55 °C , non-freezing
(32 to 130 °F)

Process pressure 1 bar relative (14,5 psi relativ)
Max. 2 bar (max. 29 psi)

Measuring method Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines)
All components are reduced at the working electrode
Almost pH independent

Chlorine sensors and transmitters for water treatment (21)

F

L

E

X

Chlorine sensors and transmitters for water treatment (22)

Digital free bromine sensorMemosens CCS55E

Digital free bromine sensorMemosens CCS55E

Memosens sensor for seawater applications and process water

Chlorine sensors and transmitters for water treatment (23)

Loading price

Prices temporarily unavailable

Price after login

Price on request

activating price

price: provide information

from € 99'999'999.99

Measuring range Trace: 0 ... 5 mg/l HOBr
Standard: 0 ... 20 mg/l HOBr
High: 0 ... 200 mg/l HOBr

Process temperature +0...55 °C (32 ... 130°F), non-freezing

Process pressure Max. 1 bar (max. 14.5 psi)

Chlorine sensors and transmitters for water treatment (26)

F

L

E

X

Chlorine sensors and transmitters for water treatment (27)

Digital ozone sensorMemosens CCS58E

Digital ozone sensorMemosens CCS58E

Memosens sensor for wastewater, process water in all industries and drinking water

Chlorine sensors and transmitters for water treatment (28)

Loading price

Prices temporarily unavailable

Price after login

Price on request

activating price

price: provide information

from € 99'999'999.99

Measuring range 0 to 2 mg/l

Process temperature +0 to 45 °C (32 to 110 °F), non freezing

Process pressure 1 bar (14.5 psi), 2 bar (29 psi) absolute

Measuring method - closed 2 electrode system
- conversion of ozone into a signal current in nA
- signal current is proportional to the concentration of ozone
- the measurement is not pH dependent

Chlorine sensors and transmitters for water treatment (31)

F

L

E

X

Chlorine sensors and transmitters for water treatment (32)

1-/2-channel transmitter Liquiline CM442

1-/2-channel transmitter Liquiline CM442

Expandable multiparameter field device for all industries

Chlorine sensors and transmitters for water treatment (33)

Loading price

Prices temporarily unavailable

Price after login

Price on request

activating price

price: provide information

from € 99'999'999.99

Input 1 to 2x Memosens digital input
2x 0/4 to 20mA input optional
2x Digital input optional

Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet

Ingress protection IP66 / IP67

Chlorine sensors and transmitters for water treatment (36)

F

L

E

X

Chlorine sensors and transmitters for water treatment (37)

1-/2-channel transmitter Liquiline CM442R

1-/2-channel transmitter Liquiline CM442R

Compact multiparameter DIN-rail and cabinet device for all industries

Chlorine sensors and transmitters for water treatment (38)

Loading price

Prices temporarily unavailable

Price after login

Price on request

activating price

price: provide information

from € 99'999'999.99

Input 1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional

Output / communication 2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet

Ingress protection Transmitter: IP20
Optional Display: IP66

Chlorine sensors and transmitters for water treatment (41)

Chlorine sensors and transmitters for water treatment (42)

Flow assembly for multi-parameter measurements Flowfit CYA27

Flow assembly for multi-parameter measurements Flowfit CYA27

Modular assembly for drinking and process water applications

Chlorine sensors and transmitters for water treatment (43)

Loading price

Prices temporarily unavailable

Price after login

Price on request

activating price

price: provide information

from € 99'999'999.99

Process temperature 0 to 60 °C (32 to 140°F)

Process pressure 0 to 4 bar (0 to 58 psi) relative

Chlorine sensors and transmitters for water treatment (46)

Bundle Chlorine sensors and transmitters for water treatment (47) Not available

Chlorine sensors and transmitters for water treatment (48)

Free chlorine process water panel

Free chlorine process water panel

Chlorine sensors and transmitters for water treatment (49) Not available

Ready-to-use panel bundle for reliable and precise monitoring of disinfection processes

Not available in your market

Straightforward installation and commissioning

Simply mount the solution, connect it to power and water and you are operational.

Simple and safe

The Memosens sensors for free chlorine and pH come pre-calibrated and ready to measure. Their non-contact, inductive signal transmission eliminates all problems due to moisture, temperature or EMC interferences.

Reliable medium flow and measurement

The Flowfit CYA27 assembly with integrated flow monitoring makes sure that your measurement is always operational.

Flexibility for future requirements

The assembly's modular design offers the maximum flexibility to upgrade your measuring points with dissolved oxygen, ORP or conductivity up to 6 variables, enabling perfect adaptation to your process requirements.

Chlorine sensors and transmitters for water treatment (2024)
Top Articles
Latest Posts
Recommended Articles
Article information

Author: Aracelis Kilback

Last Updated:

Views: 5807

Rating: 4.3 / 5 (44 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Aracelis Kilback

Birthday: 1994-11-22

Address: Apt. 895 30151 Green Plain, Lake Mariela, RI 98141

Phone: +5992291857476

Job: Legal Officer

Hobby: LARPing, role-playing games, Slacklining, Reading, Inline skating, Brazilian jiu-jitsu, Dance

Introduction: My name is Aracelis Kilback, I am a nice, gentle, agreeable, joyous, attractive, combative, gifted person who loves writing and wants to share my knowledge and understanding with you.